Pile Capacity Calculator: Bearing and Skin Friction

Calculate ultimate and allowable pile capacity for driven and bored piles. Determine shaft friction and end bearing contributions.

Last updated: January 2026

Units
Pile Properties
Soil Conditions
Pile Capacity Insufficient

Ultimate Capacity

3330

kN

Allowable Capacity

1332

kN

Capacity Breakdown
End Bearing (Qb)1909 kN
Skin Friction (Qs)1421 kN
Utilization Ratio113%
SettlementNot estimated - requires specialist analysis or a pile load test
Pile Details
Base Area0.283 m²
Shaft Surface Area28.27 m²
Concrete Volume4.24 m³

Notes:

  • Verify with site-specific geotechnical report
  • Consider pile group effects
  • Negative skin friction may apply
  • Pile load testing recommended
Your results
Email me this calculation
Leave your email and the Arkan team will send you this calculation. The calculator stays free and needs no sign-up.

We use your email to send this calculation. See our Privacy Policy.

IMPORTANT DISCLAIMER

This calculator provides PRELIMINARY ESTIMATES ONLY and is intended for planning and budgeting purposes. Results should NOT be used for final structural design or construction without verification by a licensed Professional Engineer (PE) or Chartered Engineer (CEng).

By using this tool, you acknowledge that:

1. All calculations are indicative and may not account for site-specific conditions, load combinations, or local code requirements.

Embed this calculator on your site

Paste this snippet into your page. The embedded calculator is free to use and links back to this page.

About This Calculator

The Pile Capacity Calculator helps geotechnical engineers and foundation designers determine safe working loads for driven and bored piles in UAE and Gulf soil conditions. Calculate ultimate pile capacity from shaft friction and end bearing contributions, with appropriate factors of safety for different pile types and installation methods.

Formula

Base area = π × (D ÷ 2)²; shaft area = π × D × L

Clay: end bearing Qb = 9 × cu × base area × end factor; skin friction Qs = α × cu × shaft area × skin factor, α = min(1, 0.5 ÷ √(cu ÷ 100))

Sand and gravel: Qb = Nq × γ × L × base area × end factor, Nq = min(2 × N, 60); Qs = β × (γ × L ÷ 2) × shaft area × skin factor, β = 0.25 + 0.01 × φ

If the water table is above the pile toe, Qs is reduced by 10% × (submerged length ÷ L)

Ultimate capacity Qu = Qb + Qs; allowable = Qu ÷ factor of safety

Utilisation = applied load ÷ allowable capacity × 100

Worked example

600 mm bored cased pile, 15 m long, in medium sand

Inputs

  • Pile type: bored (cased), diameter 600 mm, length 15 m
  • Soil: medium dense sand (built-in values N = 25, γ = 18 kN/m³, φ = 32°)
  • Water table 5 m below the pile head
  • Applied load 1,500 kN, factor of safety 2.5

Steps

  1. Base area = π × 0.3² = 0.283 m²; shaft area = π × 0.6 × 15 = 28.27 m²; concrete volume = 0.283 × 15 = 4.24 m³.
  2. Nq = min(2 × 25, 60) = 50. Bored piles use an end factor of 0.5, so Qb = 50 × 18 × 15 × 0.283 × 0.5 = 1,909 kN.
  3. β = 0.25 + 0.01 × 32 = 0.57 and the mid-length effective stress is 18 × 7.5 = 135 kPa, so with a skin factor of 0.7 the dry-soil skin friction is 0.57 × 135 × 28.27 × 0.7 = 1,523 kN.
  4. The water table is 10 m above the toe, so Qs is reduced by 10% × 10 ÷ 15 = 6.7%, giving Qs = 1,421 kN.
  5. Ultimate capacity = 1,909 + 1,421 = 3,330 kN; allowable = 3,330 ÷ 2.5 = 1,332 kN.
  6. Utilisation = 1,500 ÷ 1,332 = 113%.

Result: Allowable capacity 1,332 kN against a 1,500 kN load: 113% utilised, so the pile is flagged as insufficient.

Assumptions and limits

  • The soil is a single uniform layer taken from a built-in list; the soil strengths (N, cu, γ, φ) are fixed values for each soil type, not site data. A real design uses the layered ground profile from the geotechnical report.
  • The pile-type end and skin factors (driven 1.0 and 1.0, CFA 0.6 and 0.8, bored 0.5 and 0.7) are simple relative factors.
  • Settlement is not estimated. It needs a recognised method or a pile load test.
  • Pile group effects, negative skin friction, lateral and uplift loads, structural capacity of the pile section and the chosen installation method are not checked.
  • The result is a screening estimate to compare options early, not a pile design and not a substitute for a pile load test or a geotechnical engineer's advice.

When to Use This Calculator

  • Designing deep foundations for high-rise buildings
  • Verifying pile capacity from load test results
  • Comparing driven vs bored pile options
  • Estimating pile lengths for tender submissions
  • Assessing pile capacity in layered soil profiles

How to Use This Calculator

1

Select Pile Type

Choose driven (precast, steel) or bored (cast-in-place, CFA) pile type.

2

Enter Pile Geometry

Input pile diameter and length (or tip elevation).

3

Define Soil Layers

Enter soil stratigraphy with SPT N-values or shear strength parameters.

4

Set Design Parameters

Specify adhesion factors, bearing capacity factors, and FOS.

5

Calculate Capacity

Get shaft friction, end bearing, and total allowable pile load.

Typical Scenarios in UAE & Gulf Projects

Tower Foundation in Business Bay

Geotechnical consultant designs 1.2m diameter bored piles for 50-story tower. Calculator determines 45m pile length required to reach rock and achieve 12,000 kN working load, with 65% shaft friction and 35% end bearing contribution.

Bridge Piling in Saudi Arabia

Foundation engineer evaluates 600mm precast driven piles for highway bridge. Tool calculates capacity in dense sand with high N-values, recommending 25m length for 3,500 kN allowable load with FOS 2.5.

Frequently Asked Questions

What factor of safety is required for piles in the UAE?

The factor of safety on pile capacity and the load testing required are set by the design code, the geotechnical report and the authority concerned. Take them from your project requirements; higher factors can apply to tension piles.

How do I choose between driven and bored piles?

Driven piles suit: Sand/gravel soils, marine works, sites without vibration restrictions. Bored piles suit: Clay soils, urban sites, large diameters (>800mm), deep rock sockets. In UAE, CFA and rotary bored piles dominate due to dense sand profiles.

What are typical pile capacities in Dubai soil conditions?

Pile capacity depends on the ground profile, the pile type, diameter and length, and must come from the geotechnical report and the pile design. The calculator gives a screening estimate from the parameters you enter; confirm it with the geotechnical engineer and pile load tests.

Last Updated: January 2026

Standards Reference: BS EN 1997-1 Eurocode 7, ASCE Standard Pile Foundation Design, API RP 2A for Offshore

Do this inside Arkan

A calculator gives you one number. Arkan keeps the quantities, inspections and payment requests for the whole project in one place, in English and Arabic.

Arkan screen: boq

Need More Than Calculators?

Arkan brings all your construction management together: BOQ tracking, payment certificates, document management, scheduling, and more. All integrated. All in one place.