Door Schedule Generator: Build a Door Schedule with Counts
Generate a door schedule with ID, location, type, material, size and fire rating, with totals by type, material and fire rating.
Last updated: January 2026
1
Total Doors
| ID | Type | Size | Location |
|---|---|---|---|
| D01 | flush | 900 x 2100mm | Office 101 |
ESTIMATION NOTICE
This calculator provides APPROXIMATE QUANTITIES for budgeting and planning purposes.
Please note:
• Wastage is included only where the tool says so. Actual waste varies with site conditions, workmanship, and material quality.
Embed this calculator on your site
Paste this snippet into your page. The embedded calculator is free to use and links back to this page.
About This Calculator
The Door Schedule Generator helps architects, contractors, and quantity surveyors list the doors of a project with their ID, location, type, material, size and fire rating, and read off the counts by type, material and fire rating for procurement and tendering. Hardware is not specified or edited here.
Formula
Total doors = number of rows in the schedule
Doors by type, material and fire rating = count of rows with each value
Worked example
Inputs
- D1: flush door, 900 × 2100 mm, solid core, no fire rating, Bedroom
- D2: 30-minute fire door, 900 × 2100 mm, solid core, 30 minute rating, Corridor, with a closer
- D3: flush door, 800 × 2100 mm, hollow core, no fire rating, Bath
Steps
- Total doors = 3.
- By type: flush 2, fire door (30 min) 1.
- By material: solid core 2, hollow core 1.
- By fire rating: none 2, 30 minutes 1.
- Hardware: a lever handle on each of the 3 doors and 1 closer.
Result: 3 doors: 2 flush and 1 fire door; 2 solid core and 1 hollow core; 3 lever handles and 1 closer.
Assumptions and limits
- Inputs and results follow the Metric/Imperial switch; formulas and worked examples are stated in metric.
- This is a schedule and counting tool, not a design tool. It records what you enter and totals it; it does not size doors or check them against any code.
- Door sizes are entered in millimetres as width × height and are shown as entered.
- Fire ratings and fire door types are labels you select. The tool does not check that a rating suits the location, frame, hardware or glazing; confirm ratings against the fire strategy and the door manufacturer's certification.
- Counts depend on consistent entry. Give each door a unique ID and use the same type, material and rating values for identical doors.
- Frames, ironmongery, finishes and prices are not calculated. The tool does not currently let you edit hardware per door.
When to Use This Calculator
- Creating door schedules for tender documentation
- Recording the fire rating labels from the approved fire strategy
- Counting doors for procurement
- Coordinating door dimensions with partition layouts
- Preparing door specifications for fit-out projects
How to Use This Calculator
Add Each Door
Add each door: ID, location, type, material, size and fire rating.
Set the Fire Rating
Pick the fire rating label the fire strategy requires.
Review the Totals
Review the totals by type, material and fire rating and the schedule table.
Typical Scenarios in UAE & Gulf Projects
An architect lists the doors of a fit-out with their type, size, material and fire rating, and reads off the counts by type and material for the tender.
A quantity surveyor lists the doors from the drawings and compares the totals by type with a subcontractor's quotation. Hardware and finishes are specified separately.
Frequently Asked Questions
What fire ratings are required for doors?
Fire door ratings are set by the fire strategy, the Civil Defence approved drawings and the applicable code for each location, so take them from the approved fire strategy and the door schedule. Fire doors need the certified door set as tested, including intumescent seals, closers and the certification marks the approval requires.
What hardware should I specify for commercial doors?
Hardware is specified by the architect or hardware consultant to suit the use, the fire rating and the project specification. This generator does not specify or edit hardware, so take it from the hardware schedule.
How do I specify acoustic doors for meeting rooms?
Acoustic doors need an STC/Rw rating from the acoustic consultant's specification. Include perimeter seals, an automatic drop seal at the threshold and solid core construction as the specification requires, and coordinate frame details with the partition rating.
Last Updated: January 2026
Standards Reference: Reference only: the generator lists and counts doors and does not check compliance with any code
